ECLSS Low Pressure Flow Control and Isolation Valves



Moog produces a variety of fluid control components used in human space vehicles as part of their environmental control and life support systems (ECLSS). The components include mechanical pressure regulators, manual and electrically actuated valves, and passive components such as quick disconnects. These components are used in high- and low-pressure breathing gas control systems, as well as liquid fluid control for thermal management.

CONTACT US >

Key Features

  • Low pressure O2 and fluids at 14.5 psi to 145 psi, with gas mass flow rates of 0.011 lbm/sec (O2), liquid mass flow rates of 0.1 lbm/sec (H2O), and volumetric flow rates of >170 ACFM O2

Electrically-actuated valves are 28 VDC devices that use brushless DC motors and solenoids to drive the units open or closed, and include normally-open / normallyclosed and latching designs. Certain designs provide position indication capability.

 

Valve

Model 52-307 & 52-311, 

52E341 & 52E342

2- and 3-way Isolation Valves

Model 50-1474

2-way Isolation Valve 

w/Manual Override

Model 50-1396 

Motorized Ball Valve – 1.5”

Model 50-1395 

Motorized Ball Valve – 2.0”

Description Torque motor design, latching

Torque motor design, latching, 

manual override

Ball valve, BLDC actuated

Redundant Ball valve, 

BLDC actuated

Media

Oxygen, Ammonia, 

Propylene Glycol, Urine

Oxygen and Nitrogen Oxygen Oxygen
Unit Mass 3.4 lbm 4.0 lbm 4.75 lbm 14.5 lbm
Dimensions (L W H) 4.8” x 2.3” x 4.5” 4.8” x 2.3” x 5.0” 5.4” x 3.9” x 5.1” 10.4” x 6.2” x 9.6”
MEOP 145 psia 145 psia 23.5 psia 8.6 psia
MDP 145 psia 145 psia 23.5 psia 8.6 psia
Factors of Safety

Proof: 1.5x MEOP; 

Burst: 2.5x MEOP

Proof: 1.5x MEOP; 

Burst: 2.5x MEOP

Proof: 1.5x MEOP; 

Burst: 2.5x MEOP

Proof: 1.5x MEOP; 

Burst: 2.5x MEOP

Design Pressure Drop

0.88 psid H2

@ 70°F & 0.1 lbm/sec

0.9 psid 0.8 psid 0.025 psid
Design Flowrate 0.1 lbm/sec H2O @ 70°F 0.018 lbm/sec N2; 0.01 lbm/sec O2 675 lbm/hr Air @ 14.9 psia, 80°F 78 ACFM Air @ 14.7 psia, 75°F
Leakage – Internal (@ MDP, GHe) < 1 x 10-3 scc/sec < 1 x 10-3 scc/sec < 1 x 10-2 scc/sec < 5 x 10-3 scc/sec
Leakage – External (@ MDP, GHe) < 1 x 10-3 scc/sec < 1 x 10-3 scc/sec < 1 x 10-3 scc/sec < 1 x 10-3 scc/sec
Temperature (Operating)  -40°F – 160°F -40°F – 160°F -15°F – 160°F +5°F – 150°F
Random Vibration 83 Grms 22 Grms 10.35 Grms

2.86 Grms* 

(analysed to 61.48 Grms)

Shock 3588 G 2100 G 3500 G 5500 G
Cycle Life 900 cycles 13000 cycles 900 cycles 860 cycles
Wetted Materials CRES, PTFE CRES, PTFE Aluminum, CRES, PTFE Aluminum, CRES, PTFE
Filtration 55 micron absolute N/A N/A N/A
Response Time (Open/Close) 100 milliseconds 100 milliseconds 2 sec 2.5 sec
Operating Voltage 26 ± 1 VDC 28 VDC 28 VDC 21 – 26 VDC
Current Draw 0.6 Amp 0.6 Amp

0.45 Amp min, 

controller limited

0.625 Amp min, 

controller limited

Position Indication No Yes No No