Series D636 and D637 - Direct Driven Valves (DDV) for flow control with analog and optional fieldbus interface
Jump To:
Features
Specifications
Resources
Related
Features:
- Directly driven by linear force motor with no pilot flow required
- Linear force motor with high force range, offering no flow limitations
- Directly driven design means pressure-independent dynamic performance
- Low current consumption at and near hydraulic null
Specifications | ||
D636 | D637 | |
Control Functions | Flow, Pressure, Flow&Pressure (p/Q), Pressure Compensated Flow, Axis (Position, Velocity, Force) | |
Mounting Pattern | ISO 4401 Size 03 (NG6) | ISO 4401 Size 05 (NG10) |
Hydraulic Data | ||
Rated Flow at ∆p 35 bar (500 psi) per land | up to 40 l/min (10.6 gpm) | up to 100 l/min (26.4 gpm) |
Maximum Flow | 75 l/min (19.8 gpm) | 180 l/min (47 gpm) |
Maximum Operating Pressure | Port P, A, B - 350 bar (5,000 psi) | |
Port T without Y - 50 bar (725 psi) | ||
Port T with Y - 350 bar (3,000 psi) | Port T with Y - 210 bar (3,000 psi) | |
Step Response Time for 0 to 100% Step | 8 ms | 14 ms |
Electrical Data | ||
Supply Voltage | 24 VDC (18 to 32 VDC) | |
Rated Signal Options | +/-10 V, +/-10 mA and 4 to 20 mA | |
Electrical Connectors | 6+PE, 11+PE | |
Options | ||
Interfaces | Fieldbus Interface | |
Additional Analoge Transducer Interfaces |